Timber Roof Batten Spacing Australian Standard

Roof Battens Metal And Timber Roofing Battens For Tile Metal Roofs

Roof Battens Metal And Timber Roofing Battens For Tile Metal Roofs

Timber Steel Framing Manual Single Span Rafter

Timber Steel Framing Manual Single Span Rafter

Timber Steel Framing Manual Single Span Roof Beam

Timber Steel Framing Manual Single Span Roof Beam

Purlin Roof Structure Engineers Edge Www Engineersedge Com

Purlin Roof Structure Engineers Edge Www Engineersedge Com

Fixing And Bracing Guidelines For Timber Roof Trusses 2015 Issue 1

Fixing And Bracing Guidelines For Timber Roof Trusses 2015 Issue 1

Exposed Rafter Tails Framing Exposed Rafters Rafter Tails Rafter

Exposed Rafter Tails Framing Exposed Rafters Rafter Tails Rafter

Exposed Rafter Tails Framing Exposed Rafters Rafter Tails Rafter

Timber battens for tile roofs must meet the requirements of as 1684 2 as 1684 3 or as 1720 1.

Timber roof batten spacing australian standard.

Handling and storage if roof battens are to be stacked and left in the open for any length of time ensure they are kept off the ground with one end elevated to drain any collected moisture. It s a place for you to share your vision of how we could develop standards better and how they could add greater value to australian society by being delivered in more user focused ways. We supply 38 x 38mm or 28 x 38mm non structural timber battens for tile roofs. Pryda australia acknowledges standards australia for permission to reproduce some of the drawings and technical content from within as4440 2004.

If additional fall protection is required on steel sheet roofs stratco ceiling battens may be fixed intermittently between stratco roofing battens giving a batten spacing no greater than 600mm. The high performance values of steel roof battens means they are an increasingly popular choice for reroofing or for new builds using tile roofs. Installation of nailplated timber trusses and as such should be read in conjunction with this standard. Edges within 1200 mm of the building edges includes ridges hips perimeter and general areas all other areas of the roof not included in edges.

Steeline roof battens are compatible with all standard roof cladding materials and it can also be used in combination with other systems such as timber. For sheet roofed houses with 900 mm rafter spacing in wind classification n4 or c2 the minimum size of f5 or mgp 10 rafters or top chords shall be 90 x 45 mm. Spans 9m to 16m crane 60 or less 1 3 to 1 2 span 1 3 to 1 2 span crane slings should be located at equal distances from the truss centreline and be approximately one third to one half truss length apart. The maximum overhang of house rafters or trusses shall not exceed 750 mm from outside of top plate to end of rafter truss.

Incubator the standards australia incubator is a sandpit for playing with new ideas and testing concepts. As 1684 residential timber framed construction is a four part australian standard covering design criteria building practices tie downs bracing and span tables for timber framing members. When assessing the required capacity of the batten rafter connection as1684 2 2010 divides the roof into two areas. It is also referred to as the timber framing code.

Crane chain for brace on crane lateral movement of truss vertical chain or cling 1 3 to 1 2 span 1 3 to 1 2 span figure 3. Refer to stratco for applications in higher wind conditions.

Architectural Roof Trusses Woodsolutions

Architectural Roof Trusses Woodsolutions

Roof Batten Splicing The Guide

Roof Batten Splicing The Guide

Https Pryda Com Au Wp Content Uploads Roof Truss Installation Guide Pdf

Https Pryda Com Au Wp Content Uploads Roof Truss Installation Guide Pdf

Pitched Roof Types Explained Cut And Truss Roofs

Pitched Roof Types Explained Cut And Truss Roofs

Source : pinterest.com